Rapid Determination of Seismic Moment and Radiated Energy - Region: Central Italy  Event List

Earthquake Location (from: INGV id: 42697472 ingv)
Region: Campi Flegrei - 2025-05-13 10:06:44 (UTC)

Laboratory of Seismology (Distav, University of Genoa) - ID: 250513100644
Posted on: 2025-05-26 05:55:51

RSNI Logo



Seismic Moment (Log): 15.22 ± 0.15
Radiated Energy (Log): 10.04 ± 0.47
Moment Magnitude MW: 4.08
Local Magnitude ML IT16: 3.47 ± 0.52
Apparent Stress [Pa]: 2.08e+5

Station Net Loc. Chan. Hypo dist. [km] ML IT16 PGA Z [cm/s2] PGA NS [cm/s2] PGA EW [cm/s2] PGV Z [cm/s] PGV NS [cm/s] PGV EW [cm/s] Log(Mo) Log(Er) Used(1)
POZT IT HN 2.6 4.2 119.800000 64.130000 105.200000 2.473000 3.467000 105.200000 - - -
POZS IT HN 2.8 4.2 149.500000 165.400000 181.100000 3.726000 8.596000 181.100000 - - -
BCLI IT HN 5.0 4.0 28.570000 33.780000 41.960000 1.047000 1.084000 41.960000 15.23 10.41 X
BAN IT HN 5.5 4.0 20.620000 25.050000 23.360000 0.715900 0.922000 23.360000 15.01 8.96 X
MPCD IT HN 6.5 3.9 22.670000 33.350000 49.700000 0.551200 0.622400 49.700000 15.17 10.25 X
NAP IT HG 7.2 4.0 7.553000 12.230000 13.880000 0.517900 0.831200 13.880000 15.31 10.13 X
CML IT HG 19.9 3.8 0.525900 0.806900 0.891200 0.024230 0.060630 0.891200 15.13 10.11 X
CNC IT HG 28.6 4.0 0.487400 0.613900 0.603000 0.041570 0.074470 0.603000 15.48 10.46 X
AVZA IT HN 56.4 4.0 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 - 9.93 X
(1) Used for the local magnitude calculation


Credits and Copyright
RAMONES (Rapid Assessment of MOmeNt and Energy Service) service is designed, developed and maintained by the seismological group of the University of Genoa. The source parameters are estimated using features extracted directly from recordings, following methodologies developed through scientific collaborations between the University of Genoa, the German Research Centre for Geosciences (GFZ-Potsdam), the University of Naples, and the Italian National Institute of Geophysics and Vulcanology (INGV).
If you use these data, please cite the original paper: doi:10.1785/0220200348
Reproduction is authorised only if the source is cited in a complete and comprehensive way.